Snap-on Panels have been designed for use in roofing, mansard and fascia applications. Snap-on Panels are designed to be installed over a waterproofed solid substrate and a minimum 3:12 roof pitch. Snap-on Panels are to be factory roll formed in continuous lengths (minimum panel length is 4 feet).

These panels are ideal for specification on applications where roof transitions are required. The simplicity of the pan design combined with in-line tension leveling provides superior flatness and allows for greater workability on site.

UL 90 Rating

Steel Snap-on Standing Seam and High Seam Panels carry a UL 90 rating for wind uplift when fastened to an underlayment assembly including 5/8" plywood or OSB (oriented strand board) laminated to rigid insulation (UL Construction No. 351 & 352). This is one of the few UL 90 Systems that does not require sealant between plywood boards. For further details contact Petersen Aluminum Corporation.

Air and Water Infiltration

Petersen Snap-on Panels meet the full performance requirements of the ASTM E 283 air infiltration test and the ASTM E 331 water penetration test when applied over a solid substrate. For complete test results, contact Petersen Aluminum Corporation.

Materials

a) 24 ga. G-90 hot-dipped galvanized steel b) .032 3105-H14 aluminum

Trim

All flashing and trim will be fabricated by manufacturer or qualified fabricator. Flashing shall be PAC-CLAD aluminum (.032-.080 gauge as specified) or PAC-CLAD steel (22 ga. or 24 ga. as specified). A 20 year, non-prorated warranty shall be supplied covering finish performance.

Curved Panels

The 1" High Snap-on Standing Seam Panel can now be curved to a concave or convex radius, with a minimum radius of 9 ft. This panel is ideal for barrel vaults and entranceways. Curved panels must be installed over a waterproofed solid substrate.

Installation

PAC-CLAD Snap-on Panels shall be installed over solid decking (5/8" plywood, nailboard insulation or equal) with an underlayment of 30# (min.) roofing felt applied horizontally from eave to ridge. Panels shall be fastened using Petersen Non-Penetrating Clips, fastening on 18" centers (max.). Minimum slope at 3:12 pitch. Consult a local architect or engineer for requirements of local codes and conditions.

  Product Features
  •Ideal for transition roofs
•Herr-Voss corrective leveled •Stiffener beads available
  Material
•30 standard colors (steel)
•20 standard colors (aluminum)
•11 standard colors (22 ga. steel)
•20 year non-prorated finish warranty ÑSmooth and stucco embossed available

• Galvalume Plus available
  UL-90 Rating
  •UL 90 rated over solid substrate (steel only ╨ up to 18╙O.C.)
•UL-790 Class A fire rated
•UL-263 fire resistance rated
  ASTM Tests
  •ASTM E331 tested
•ASTM E283 tested
   

A complete ManuSpec¿ specification is available on request from Petersen Aluminum Corporation

 

Braxton╒s Animal Works Wayne, PA
Owners: Bill Braxton, John Braxton, Dave Braxton
Architect: John Burzynski Associates, Inc.
General Contractor: Carroll Contractors, Inc.
Roofing Contractor: DDP Contracting Company, Inc.
Profile: Snap-Clad
Color: Aged Copper


Top Photo:
International Teams Elgin, IL
Architect: Burnidge Cassel Architects
General Contractor: Owner Rep / Mr. Richard Becker Sheet Metal
Contractor: Anthony Sheet Metal
Color: Hemlock Green / Sandstone
Profile: Snap-Clad

Bottom Photo:
Capitol One Building Irving, TX
General Contractor: Rogers-O╒Brien Construction
Roofing Contractor: Seyforth Roofing, Inc.
Color: Charcoal Gray, Slate Gray
Profile: Snap-Clad, Flush Panel